Synchronized Metadata [VCon IG]

Some VidiCore metadata fields are automatically created and constantly synchronized with VidiControl. These are attached to the VidiCore Item which represents the VidiControl Recording (Booking Component).

Changes on VidiControl side are kept in sync with VidiCore.

VidiCore Metadata

Type

VidiControl source

V3_RecordingStart

Datetime

Start of Recording

V3_RecordingEnd

Datetime

End of Recording

V3_RecordingState

String Exact

One of
Pending, InProgress, Done, Error, Virtual, DoneWithErrors, NotAssigned, BeforeStart, VirtualError, see Booking Component States

V3_RecordingDestination

String Exact

Device Custom Name (if set) or Recorder Port Name

V3_RecordingSource

String Exact

InPort custom label (if set) or InPort Label

V3_RecordingPool

String Exact

Pool name

VC_ChunkId

String Exact

SiteID + internal ChunkId

VC_BookingComponentId

String

Chunk Id (External Id)

VC_BookingId

String

Booking Id (External Id)

VC_BookingDefinitionId

String

BookingDefinitionId (External Id)

Note, that there is only a one way synchronization from VidiControl to VidiCore and not vice versa.

Details of the synchronization can be configured using Config Values, refer to these Fields:

  • TechDataBackgroundIntervalInSeconds

  • TechDataProcessingIntervalInSeconds

  • TechDataRemoveUnsuccessfullyInSeconds